Skip to main content
Your Saved For Later list is empty.
My Favorites

BlazeCut T-Series T400E Automatic Fire Suppression System

Item #: BZT-T400E
There are no reviews yet Write a review
Price: $753.99 inc GST
Retail Price: ##RETAILPRICE## inc GST
    Points to Purchase:5027
    The product is in stock Availability: Stocked(Local Warehouse)
    Usually ships In a day

    About This Item

    • Compact & Versatile: BlazeCut Tube protects A, B, C, and electrical fires with no cylinder required, fitting inside enclosures.
    • Automatic & Independent: Heat‑sensitive tube activates at high temperatures, operates 24/7 without power, and requires zero maintenance.
    • Safe & Effective: Uses globally accepted HFC‑227ea agent, harmless to people and equipment, with long service life up to 10 years.
    • Simple Installation & Monitoring: Easy to secure with cable ties/clamps, includes pressure gauge and optional switch for added safety functions.
    BlazeCut T-Series

    T400E automatic fire suppression for enclosed equipment

    A self-contained tube system for small enclosed compartments. The T400E has a 422 cm system length and contains 1.00 kg of HFC-227ea agent.

    Where the T400E fits

    This model is commonly considered for the largest enclosed electrical, machinery, vehicle and marine spaces covered by the MindKits T-Series range. Suitability depends on the measured internal volume, enclosure ventilation, ambient temperature and installation layout.

    • Electrical application maximum at 20°C: 1.82 m³
    • Engine application maximum at 20°C: 1.39 m³
    • System length: 422 cm
    • Agent amount: 1.00 kg

    Check the size before ordering

    Use the calculator for a volume-based starting point, or review the complete BlazeCut application guide.

    Use the BlazeCut size calculator Explore BlazeCut applications

    Supplier sizing limits are calculated at 20°C using 7% design concentration for electrical applications and 9% for engine applications. Lower temperatures reduce coverage potential. The T-Series is intended for enclosed or minimally ventilated spaces and is not suitable for open areas. Confirm unusual, highly ventilated, safety-critical or compliance-led installations before purchase.

    Sizing and Selection

    Measure internal width × height × depth to calculate enclosure volume, then compare the electrical or engine maximums below. For a guided result, use the BlazeCut size calculator. The enclosure must be enclosed or minimally ventilated; the T-Series is not suitable for open areas.

    Model* Electrical Fires**
    @ 20°C (68°F)
    Engine Fires**
    @ 20°C (68°F)
    Amount of Agent System Length Operation Temperature Activation Temperature
    T025E 0.09 m³ / 3.18 ft³ 0.09 m³ / 3.18 ft³ 0.05 kg ± 2 g / 0.11 lb ± 0.07 oz 28 cm / 11.02 in

    -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F
    T050E 0.18 m³ / 6.36 ft³ 0.14 m³ / 4.94 ft³ 0.10 kg ± 2 g / 0.22 lb ± 0.07 oz 53 cm / 20.87 in

    -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F
    T100E 0.46 m³ / 16.24 ft³ 0.35 m³ / 12.36 ft³ 0.25 kg ± 5 g / 0.55 lb ± 0.17 oz 113 cm / 44.48 in

    -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F
    T200E 0.91 m³ / 32.14 ft³ 0.69 m³ / 24.37 ft³ 0.50 kg ± 5 g / 1.10 lb ± 0.17 oz 215 cm / 84.64 in -40°C to +90°C / -40°F to 194°F 105°C ± 3°C / 221°F ± 37°F
    T300E 1.37 m³ / 48.38 ft³ 1.04 m³ / 36.73 ft³ 0.75 kg ± 10 g / 1.65 lb ± 0.35 oz 319 cm / 125.59 in

    -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F
    T400E 1.82 m³ / 64.27 ft³ 1.39 m³ / 49.09 ft³ 1.00 kg ± 10 g / 2.20 lb ± 0.35 oz 422 cm / 166.14 in

    -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F

    T500E 2.28 m³ / 80.52 ft³ 1.73 m³ / 61.09 ft³ 1.25 kg ± 10 g / 2.76 lb ± 0.35 oz 526 cm / 207.09 in -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F

    T600E 2.73 m³ / 96.41 ft³ 2.08 m³ / 73.45 ft³ 1.50 kg ± 10 g / 3.31 lb ± 0.35 oz 630 cm / 248.03 in -40°C to +90°C / -40°F to 194°F

    105°C ± 3°C / 221°F ± 37°F

    T025ES 0.09 m³ / 3.18 ft³ 0.09 m³ / 3.18 ft³ 0.05 kg ± 2 g / 0.11 lb ± 0.07 oz 35 cm / 13.78 in
    -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T050ES 0.18 m³ / 6.36 ft³ 0.14 m³ / 4.94 ft³ 0.10 kg ± 2 g / 0.22 lb ± 0.07 oz 60 cm / 23.62 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T100ES 0.46 m³ / 16.24 ft³ 0.35 m³ / 12.36 ft³ 0.25 kg ± 5 g / 0.55 lb ± 0.17 oz 120 cm / 47.24 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T200ES 0.91 m³ / 32.14 ft³ 0.69 m³ / 24.37 ft³ 0.50 kg ± 5 g / 1.10 lb ± 0.17 oz 222 cm / 87.40 in -20°C to +80°C / -4°F to 176°F 100°C ± 2°C / 212°F ± 36°F
    T300ES 1.37 m³ / 48.38 ft³ 1.04 m³ / 36.73 ft³ 0.75 kg ± 10 g / 1.65 lb ± 0.35 oz 326 cm / 128.34 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T400ES 1.82 m³ / 64.27 ft³ 1.39 m³ / 49.09 ft³ 1.00 kg ± 10 g / 2.20 lb ± 0.35 oz 429 cm / 168.89 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T500ES 2.28 m³ / 80.52 ft³ 1.73 m³ / 61.09 ft³ 1.25 kg ± 10 g / 2.76 lb ± 0.35 oz 533 cm / 209.84 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F
    T600ES 2.73 m³ / 96.41 ft³ 2.08 m³ / 73.45 ft³ 1.50 kg ± 10 g / 3.31 lb ± 0.35 oz 637 cm / 250.79 in -20°C to +80°C / -4°F to 176°F
    100°C ± 2°C / 212°F ± 36°F

    *Letter “S” in model designation stands for an integrated pressure switch that allows connection of a signaling device of to perform a shutdown operation at time of agent discharge. TxxxE does not require power.

    ** Calculated design concentration 7% (Electrical Fires) and 9% (Engine Fires) and an ambient temperature of 20°C (68°F) for the enclosure. Please note if a lower temperature is present the coverage potential will be reduced, please contact your local BlazeCut agent for further information.

    • 1 × BlazeCut T-Series automatic fire suppression system
    • Nylon straps
    • Stickers